Cargo Discharge & Heating
Overview
CII allowance for Cargo Discharging and Cargo Heating is lost if bunker consumption is not reported under the correct column in the Metaweave Events / Used For / Bunker ROB sections. Incorrect attribution directly affects the vessel’s overall CII rating.
Regulatory Background
The following deductions from attained CII are defined in MEPC.355(78):
| Parameter | What it covers |
|---|---|
| FC_electrical,j | Mass (g) of fuel type j consumed for electrical power production — deductible for discharge pumps on tankers |
| FC_Boiler,j | Mass (g) of fuel type j consumed by the oil-fired boiler — deductible for cargo heating and cargo discharge on tankers |
| FC_others,j | Mass (g) of fuel type j consumed by stand-alone engine-driven cargo pumps during discharge — deductible for tankers |
Ships Fitted with Framo or Marflex Pumps
Cargo Discharge — Framo / Marflex
-
Book all Power Pack consumption under L/D
Report the consolidated fuel consumption of all Diesel and Electric Power Packs under Events → L/D for the relevant fuel grade.
-
Remove Power Pack share from the Generator column
Any consumption attributed to Power Packs during cargo discharge must not remain in the Generator column. Move the Power Pack portion to L/D.
Example:
Item Value Total Generator consumption 4.8 MT Calculated Power Pack consumption 1.2 MT Report in Metaweave as:
Column Value Generator 3.6 MT L/D 1.2 MT
Cargo Heating — Framo / Marflex
Cargo heating is reported only when heating cargo in cargo tanks (using steam coils or deck heaters). It is not reported when heating slops stowed in Slop / ROT tanks.
-
Book all Boiler consumption under Cargo Heating
All Boiler consumption for Cargo Heating must be reported under the Cargo Heating column.
-
Move Power Pack share from Generator and L/D to Cargo Heating
Calculated consumption for Power Packs used for cargo circulation during Cargo Heating must not be included in Generator or L/D. It must be added to Cargo Heating.
Example:
Item Value Total Generator consumption 4.5 MT Total Boiler consumption 7.2 MT Calculated Power Pack consumption 1.2 MT Report in Metaweave as:
Column Value Generator 3.3 MT Cargo Heating 8.4 MT (= 1.2 + 7.2) Boiler 0 MT -
In-Port Cargo Heating
If Cargo Heating is conducted In Port, report the consolidated consumption of all Diesel / Electric Power Packs and the Boiler under the single Cargo Heating category for the appropriate event and fuel grade, following the notes above.
Framo / Marflex Flowchart
flowchart TD A[Start: Cargo Operation\nFramo / Marflex vessel] --> B{Operation type?}
B --> C[Cargo Discharge] B --> D[Cargo Heating]
C --> C1[Event type = DISCHARGING] C1 --> C2[Calculate Power Pack\nconsumption] C2 --> C3[Book Power Pack share → L/D column] C3 --> C4[Book remainder → Generator column] C4 --> C5[CII deduction: FC_electrical via L/D]
D --> D1{In Port?} D1 -- No --> D2[Calculate Power Pack\ncirculation share] D2 --> D3[Add Power Pack share\nto Boiler total] D3 --> D4[Book combined total\n→ Cargo Heating column] D4 --> D5[Book Generator remainder\n→ Generator column\nBoiler = 0 MT] D5 --> D6[CII deduction: FC_Boiler\n+ FC_electrical via Cargo Heating]
D1 -- Yes --> D7[Book all Power Pack\n+ Boiler consumption\n→ Cargo Heating column] D7 --> D6Ships Fitted with C.O.P. (Steam-Turbine Cargo Pumps)
Cargo Discharge — COP
-
Book entire Boiler consumption under L/D
Report the fuel consumption of the Boiler used for cargo discharging (via COP) under Events → L/D for the relevant fuel grade.
Cargo Heating — COP
Cargo heating is reported only when heating cargo in cargo tanks.
-
Book entire Boiler consumption under Cargo Heating
Report the entire Boiler consumption under the Cargo Heating column for the relevant fuel grade.
-
In-Port Cargo Heating
If Cargo Heating is conducted In Port, report the entire Boiler consumption under Events → Cargo Heating for the appropriate event and fuel grade.
COP Flowchart
flowchart TD A[Start: Cargo Operation\nCOP Steam-Turbine vessel] --> B{Operation type?}
B --> C[Cargo Discharge] B --> D[Cargo Heating]
C --> C1[Event type = DISCHARGING] C1 --> C2{Boiler also used for\nIGS or domestic?} C2 -- Yes --> C3[Still book 100% of\nBoiler consumption → L/D] C2 -- No --> C3 C3 --> C4[CII deduction: FC_Boiler via L/D]
D --> D1{Cargo in Slop tanks?} D1 -- No --> D2[Book Boiler consumption\n→ Cargo Heating column] D1 -- Yes --> D2 D2 --> D3{In Port?} D3 -- No --> D4[Report under Cargo Heating\nin At-Sea / port event] D3 -- Yes --> D5[Report under Events →\nCargo Heating for that event] D4 --> D6[CII deduction: FC_Boiler\nvia Cargo Heating] D5 --> D6